A dynamic mechanical analyzer (DMA) measures the mechanical properties of materials as a function of time, temperature, and frequency. By applying force to the material in a dynamic oscillating environment to induce deformation, it can measure the viscoelasticity of the material and the functional relationship of this viscoelasticity with parameters such as temperature, time, frequency, stress, atmosphere, or a combination of these parameters. It is widely used in fields such as plastics, rubber, films, fibers, coatings, ceramics, glass, metal materials, and composite materials.
It can quickly and conveniently characterize the relationship between the dynamic thermomechanical properties of materials and frequency,temperature and time.
With a modular design, it can be equipped with a cooling system and a variety of sample holders,including custom special configurations.
The ergonomic under-hung sample loading design makes it easy to replace different types of holders.
The instrument status can be viewed in real-time through the touch screen.
It can support lens force measurement simultaneously.
The furnace body is airtight and compatible with inert atmosphere.
Data related to material rigidity and damping properties;
Data related to the composition and structure of polymer mixtures (compatibility);
Glass transition temperature of highly cross-linked/amorphous/semi-crystalline polymers and composite materials;
Curing/post-curing;
Aging;
Creep and relaxation;
Stress and strain scanning;
Multi-frequency testing;
Predicting material behavior using the time-temperature superposition (TTS) function;
Intrusion testing.
Sample holders: Three-point bending sample holder, single/double cantilever sample holder, tensile sample holder, shear sample holder, etc.
Liquid nitrogen cooling: Used to achieve rapid cooling to extremely low temperatures, expanding the range of sample analysis.
Rapid air cooling
Temperature Range | -150℃~600℃ |
Maximum Applied Force | 50N |
Loading Frequency | 100Hz |
Amplitude Range | 2.5mm |
Temperature Accuracy | ±0.1℃ |
Heating Rate | 0.1~20℃/min(It adopts dual closed-loop self-learning intelligent PID temperature control to achieve linear temperature rise.) |
Sensitivity | 0.01μm |
Cooling Equipment | Compressed air and liquid nitrogen refrigeration |
Testing Atmosphere | The mass flow controller controls the flow rate in the range of 0-200ml/min. Two channels of gas with stable pressure and flow can be automatically switched during the experiment. Atmosphere options include inert, oxidizing, reducing, static and dynamic. Gas flow rate ranges from 0 to 200mL/min. The mass flow controller is equipped with a self-calibration function based on the density of different gases. |
Sample Range | High 0.3-25mm, Diameter≤10mm |
Displacement Resolution | 0.1μm |
Operating Mode | Expansion, Contraction, Bending, Penetration |
Special Accessories | Humidity Accessory |
Data Display Mode | color LCD display. The instrument automatically collects and processes data via a computer, and automatically records, stores, and prints the thermal expansion coefficient, linear expansion, linear variation percentage-time curves, linear variation percentage-temperature curves, as well as data and table curves. |