Beijing HENVEN Experimental Equipment Co., Ltd.
Beijing HENVEN Experimental Equipment Co., Ltd.
  • Microcomputer Differential Thermal Balance (Comprehensive Thermal Analyzer)
  • Microcomputer Differential Thermal Balance (Comprehensive Thermal Analyzer)
  • Microcomputer Differential Thermal Balance (Comprehensive Thermal Analyzer)
  • Microcomputer Differential Thermal Balance (Comprehensive Thermal Analyzer)

HCT-1/HCT-2/HCT-3/HCT-4 Microcomputer Differential Thermal Balance(Comprehensive Thermal Analyzer)

It is mainly used to measure physical and chemical changes related to heat, such as studying changes including the melting point, heat of fusion, crystallization and heat of crystallization, heat of phase transition reaction, thermal stability (oxidation induction period), glass transition temperature, adsorption and desorption, content analysis of components, decomposition, combination, dehydration, and additives of substances.

Instrument Feature of HCT-1/HCT-2/HCT-3/HCT-4 Microcomputer Differential Thermal Balance(Comprehensive Thermal Analyzer)

  • 01
    1

    Heat-flux DSC: Data acquisition method, which plots a curve of energy versus temperature.

  • 02
    2

    Users can independently calibrate the accuracy of temperature, energy, and thermogravimetry using standard samples.

  • 03
    3

    The atmosphere control system employs mass flow controllers, enabling switching between three channels of pressure-stabilized and flow-stabilized gases during experiments. It offers high precision, excellent repeatability, and rapid response (custom atmosphere control systems resistant to various corrosive gases are available).

  • 04
    4

    Accommodates both micro-samples and large-volume samples (maximum sample size up to 5g by replacing the support rod), meeting testing requirements for diverse samples under varying conditions.

  • 05
    5

    The entire measurement process is fully automated, with automatic plotting. Its comprehensive software supports routine data processing for DTA, TG, DTG, and DDTG, as well as specialized analyses (e.g., DTA peak area calculation, enthalpy determination, kinetic parameter computation, data comparison, activation energy calculation via multiple algorithms, glass transition temperature measurement, and specific heat determination by comparative methods).

  • 06
    6

    During sample data collection, the system allows screenshot capture at any time and automatically adjusts the measurement range based on output signal intensity.

  • 07
    7

    Large-screen LCD display, which displays the instrument status and data in real time. It is equipped with two sets of thermocouples: one set displays the sample temperature during operation, and the other set displays the furnace temperature in real time (regardless of whether the heating furnace is working or not).

  • 08
    8

    Our company can promptly develop customized software based on calculation formulas or methods provided by users.

  • 09
    9

    Independently developed constant-temperature controllers, constant-temperature connectors for gas chromatography and mass spectrometry, and constant-temperature zones ensure reliable secondary detection of tar and various reaction gases.

Instrument Parameter of HCT-1/HCT-2/HCT-3/HCT-4 Microcomputer Differential Thermal Balance(Comprehensive Thermal Analyzer)

The horizontal axis can be scaled by either temperature or time

The vertical axis can be scaled by either absolute weight or percentage

The liquid crystal display (LCD) shows in real time the furnace temperature, sample temperature, mass, gas circuit status, etc

It features step cooling curve plotting and crystallization kinetics calculation capabilities

HCT-2.HCT-3 and HCT-4can be held at constant temperatures of 1250℃, 1450℃, and 1550℃ for 72 hours respectively

DSC Parameters

DSC Range

±1mW~±500mW

DSC Accuracy

±0.1μW

Temperature Parameters


Temperature Range

HCT-1:RT~1150℃

HCT- 2:RT~1250℃

HCT- 3:RT~1450℃

HCT-4:RT~1550℃

Temperature Accuracy

±0.1℃

Heating Rate

0.1℃/min~100℃/min

Balance Parameters(TG)

Measurement Range

1mg to 200mg; with replaceable support rods, the range can be adjusted from 0 to 5g

Resolution

0.1μg

Thermogravimetric Noise

<0.1μg

Vacuum Degree (The Instrument Is Inherently Equipped With Vacuum Sealing Provisions)

With the optional vacuum unit, a pressure of 2.5×10² Pa can be achieved

Atmosphere Control System

It adopts a mass flow controller (an atmosphere control system resistant to various corrosive gases can be customized)

Constant Temperature Controller, Constant Temperature Gas Chromatography And Mass Spectrometry Connectors; Constant Temperature Zone (Optional)

Constant Temperature Range:RT~200℃

Differential Thermal Parameters

Measurement Range

±10μv~±2000μv

DTA Resolution

0.01μv

Crucible

Standard configuration: ceramic crucibles of 0.06mL or 0.12mL

Optional configurations: aluminum crucibles, graphite crucibles, quartz crucibles, platinum crucibles


HENVEN Provides High-Quality Thermal Analyzers for You!